Loading... Please wait...Implant Systems
Shop by Component

Cement-on Crown (COC) abutments and restorative components for Keystone (Lifecore) Stage-1 single-stage implants, RDS 4.8mm and WDS 6.5mm connections. Abutments machined from Grade 23 titanium in Bergenfield, New Jersey.
The Stage-1 implant connection is a locking taper with no rotational index (non-engaging), so the implant is restored at the abutment level. Titan does not carry scan bodies for any implant system.
Implant only, nothing seated

No coping fits the implant itself.
Order: a COC Abutment, 4.8mm RDS or 6.5mm WDS, in 4.0, 5.5 or 7.0mm height.
Original Indexed Abutment seated
Low (1.5mm) abutment with an octagon on top, for screw-retained work. Remove it with the .062'' Hex Driver.
WDS: we do not carry indexed parts — restore with a COC abutment instead.
RDS: IS-REOAA-AL-LC analog, IS-48IAPS-LC plastic sleeve, ITI-48EOSLIAF-LC titanium sleeve.
Original-design COC Abutment seated



Tapered post, 4.0 / 5.5 / 7.0mm heights, cement-retained.
RDS: IS-RSAA-LC analog, IS-RSATC-LC coping, IS-RNSAPS-LC sleeve
WDS: ITI-WNAA-LC analog, IS-WNSATC-LC coping, IS-WNSAPS-LC sleeve
Titan Design COC Abutment seated

Not interchangeable with original-design parts.
RDS: TN-ISA-LC abutment, TN-SAA-LC analog, TN-48PS-LC sleeve
WDS: TN-WNISA-LC abutment, TN-WNSAA-LC analog, TN-65PS-LC sleeve
Not sure what's seated? Call us with the implant catalog number from the patient record.
Three prep heights (4.0, 5.5, 7.0mm) virtually eliminate abutment prepping. Torque to 30Ncm. Restore with:
Analog
Coping
Plastic Sleeve
Also recommended: Thumb Knob, 30Ncm Torque Wrench.
Restoring an original indexed abutment (RDS only): analog, plastic sleeve, titanium locking sleeve — sleeves include a Ti screw; torque screw to 20Ncm.


Stage-1 is a single-stage, tissue-level implant: the smooth neck (1.8mm or 2.8mm collar) passes through the tissue. The 4.8mm implant was made on both connections — RSR48xx is RDS, RSW48xx is WDS — so confirm with the catalog number.
| Implant size | 1.8mm collar | 2.8mm collar |
|---|---|---|
| 3.3mm implant | ||
| 3.3 x 8mm | RSR3308-2K | RSR3308-3K |
| 3.3 x 10mm | RSR3310-2K | RSR3310-3K |
| 3.3 x 12mm | RSR3312-2K | RSR3312-3K |
| 3.3 x 14mm | RSR3314-2K | RSR3314-3K |
| 4.1mm implant | ||
| 4.1 x 8mm | RSR4108-2K | RSR4108-3K |
| 4.1 x 10mm | RSR4110-2K | RSR4110-3K |
| 4.1 x 12mm | RSR4112-2K | RSR4112-3K |
| 4.1 x 14mm | RSR4114-2K | RSR4114-3K |
| 4.1 x 16mm | RSR4116-2K | RSR4116-3K |
| 4.8mm implant | ||
| 4.8 x 8mm | RSR4808-2K | RSR4808-3K |
| 4.8 x 10mm | RSR4810-2K | RSR4810-3K |
| 4.8 x 12mm | RSR4812-2K | RSR4812-3K |
| 4.8 x 14mm | RSR4814-2K | RSR4814-3K |
| 4.8 x 16mm | RSR4816-2K | RSR4816-3K |
| Implant size | 1.8mm collar | 2.8mm collar |
|---|---|---|
| 4.8mm implant | ||
| 4.8 x 8mm | RSW4808-2K | RSW4808-3K |
| 4.8 x 10mm | RSW4810-2K | RSW4810-3K |
| 4.8 x 12mm | RSW4812-2K | RSW4812-3K |
| 4.8 x 14mm | RSW4814-2K | RSW4814-3K |
| 5.5mm implant | ||
| 5.5 x 8mm | RSW5508-2K | RSW5508-3K |
| 5.5 x 10mm | RSW5510-2K | RSW5510-3K |
| 5.5 x 12mm | RSW5512-2K | RSW5512-3K |
| 5.5 x 14mm | RSW5514-2K | RSW5514-3K |
| 6.3mm implant | ||
| 6.3 x 8mm | RSW6308-2K | — |
| 6.3 x 10mm | RSW6310-2K | — |
Reading the number: RSR = RDS (4.8mm) connection, RSW = WDS (6.5mm) connection. The first two digits are the implant diameter, the next two the length, and the suffix the collar (-2K = 1.8mm, -3K = 2.8mm). Example: RSR4110-3K is a 4.1 x 10mm implant with a 2.8mm collar on the RDS connection.
Also recommended: Thumb Knob (TK) for hand-tightening, and a 30Ncm torque wrench for final seating.
We do not carry scan bodies for any implant system. The Stage-1 connection is a locking taper with no rotational index, so no coping can index to the implant. Seat a COC Abutment and take the impression at abutment level with the transfer coping.
Use the .062'' Hex Driver — it fits both RDS and WDS original indexed abutments (and fixed-detachable abutments). Once the abutment is out, restore with a COC Abutment of the matching connection.
No. Indexed abutment components are available for the RDS connection only: IS-REOAA-AL-LC (analog), IS-48IAPS-LC (plastic sleeve) and ITI-48EOSLIAF-LC (titanium locking sleeve). For a WDS implant, remove the indexed abutment with the .062'' driver and restore with a WDS COC Abutment.
No. TN- analogs and plastic sleeves fit Titan Design COC Abutments only, and IS-/ITI- components fit the original-design abutments. Match the parts to the abutment that is seated.
Keystone (Lifecore) Stage-1 single-stage implants. RDS 4.8mm connection: 3.3, 4.1 and 4.8mm implants. WDS 6.5mm connection: 4.8, 5.5 and 6.3mm implants. The 4.8mm implant came on both connections, so check the catalog number (RSR = RDS, RSW = WDS). Per the Keystone catalog, Stage-1 connections share geometry with Straumann ITI Regular Neck Ø4.8mm and Wide Neck Ø6.5mm implants.
COC Abutments: 30Ncm. Indexed abutment sleeve screws: 20Ncm. Hand-tighten with the Thumb Knob first, then verify with a torque wrench.
Disclaimer: Lifecore® and STAGE-1® are registered trademarks of Keystone Dental, Inc. Straumann® and ITI® are registered trademarks of Institut Straumann AG. Titan Implants, Inc. is an independent manufacturer of compatible prosthetic components. References to trademarked names are used solely to indicate product compatibility. Titan Implants is not sponsored by, affiliated with, or endorsed by Keystone Dental, Inc. or Institut Straumann AG.
← Browse compatible parts using the menu on the left under "Shop All Stores"
Titan Implants carries compatible restorative components for 20+ active and legacy implant systems — including discontinued brands. If you don't see your system, call us.
20+ systems Questions? Call us: 1-201-439-0470