Titan Implants ZimVie Biomet 3i Certain Compatible Straight Locking Abutment 4.0mm Body 4.1mm Blue Platform Internal Hex with Ti Screw (T-4ISLIAF)

  • ZimVie / Biomet 3i-compatible 4.0mm Internal Hex Straight Locking Abutment by Titan Implants
  • ZimVie / Biomet 3i-compatible 4.0mm Internal Hex Straight Locking Abutment — complete set view — Titan Implants
  • ZimVie / Biomet 3i-compatible 4.0mm Internal Hex Straight Locking Abutment — complete set view — Titan Implants
Price:
$59.99
SKU:
T-4ISLIAF
Shipping:
Calculated at checkout
✓ USA-Made | ✓ Precision machined | ✓ Compatible with 20+ active & legacy systems | ✓ Same-day shipping available


*Click here for Terms and Conditions of FREE SHIPPING

Product Description

  Titan Implants Inc carries two options of straight abutments available to restore 3i Certain implants: the Titan Straight Locking Implant Abutment Flat which comes with a flat side surface, collar heights 1,2,3, and 4mm, two emergence profile diameters and prep height of 8mm. The other is the Modifiable abutment, (SKU#T-4IMA-01) which is an abutment with a wide emergence profile that can be re-shaped to the desired form for individually fabricated cementable crown and bridge restorations and telescopic crown restorations. Implant axis divergences of maximum 20° are compensated by inserted bridge restorations and suitably adapted forming. The modifiable abutment is available in a 6.5mm emergence profile for platform diameters 3.4mm (3.25mm diameter), 4.1mm, 5.0mm, and 6.0mm.

 

A two-piece engaging straight abutment for cement-retained single crowns and splinted multi-unit restorations on the ZimVie / Biomet 3i Certain internal hex connection, 4.1mm seating surface. The hex engages the implant’s anti-rotation geometry, so the abutment is indexed to the fixture and will not spin under function. A flat side on the axial wall gives the crown a positive path of insertion and a repeatable seat for try-in. Supplied with a titanium fixation screw.

Which implants use the 4.1mm platform?

The Certain 4.1mm seating surface is found on 4.0mm diameter Certain implants and on platform-switched implants whose reference number reads 5/4. On a 3i platform-switched designation the second figure identifies the prosthetic platform, not the implant body — so a 5/4 implant restores on 4.1mm components, not 5.0mm. If you are unsure which platform is in the mouth, send the implant reference number or the surgical record and we will identify the platform before you order.

Specifications

  • Connection: Certain internal hex, 4.1mm seating surface
  • Engagement: locking (engaging) — indexed to the implant hex
  • Axial geometry: flat side for path of insertion
  • Includes: titanium fixation screw
  • Material: Grade 23 ELI titanium (Ti-6Al-4V ELI)
  • Driver: 0.050" hex
  • Implant body diameter: 4.0mm (also 5/4 platform-switched)
  • Machined in Bergenfield, New Jersey

Clinical notes

  • This SKU is the locking (engaging) design only — the hex is always engaged, and there is no non-locking version of it. Where a non-engaging component is needed there are two routes on the 4.1mm platform: the bar abutment for laser welding (T-4ICA-12) for screw-retained bars and fixed-detachable frameworks, or the castable non-hex abutment where the component is to be waxed and cast. Neither indexes to the implant hex, so both tolerate the inter-implant divergence that defeats a locking abutment on a splinted span.
  • Choose collar height against soft-tissue thickness measured at the deepest point of the sulcus, so the cement margin finishes at or just below the free gingival crest.
  • Horizontal reference grooves on the body assist height measurement and controlled reduction when the abutment is prepared intraorally.

Recommended accessory

The Titan Implants Locator Pin (M1.6-ILP-22) is the correct pin for the Certain internal hex connection. Thread the pin into the fixture first to check parallelism and available height, then slide this component down the pin and into place — useful in posterior sites and wherever access or visibility is limited. Withdraw the pin and replace it with the fixation screw. The locator pin works with two-piece components only.

Note: this product requires a 0.050" hex screwdriver, sold separately.

Other 4.1mm Certain components

Modifiable Abutment (T-4IMA-01) · Temporary Abutment (T-4ITA) · Impression Coping (T-4CIIC) · Implant Analog (T-4CIA) · Healing Abutment (T-4IHA) · Ball Head Attachment (T-4IBHA) · Bar Abutment (Laser Weld), Laser Weld (T-4ICA-12)

Compatibility: Machined to the referenced system’s original prosthetic specifications for the ZimVie / Biomet 3i Certain internal hex connection, 4.1mm platform. Titan Implants, Inc. is an independent manufacturer. ZimVie, Biomet 3i, Certain and QuickSeat are trademarks of their respective owners; Titan Implants is not affiliated with, sponsored by, or endorsed by ZimVie Inc. or its affiliates.

 

  • Designed for 3i Certain 4.1mm platform internal hex implants
  • Straight locking design prevents abutment rotation
  • Precision-machined internal hex ensures excellent fit
  • Multiple collar heights and emergence profiles for optimal esthetics
  • Includes titanium screw for secure torque and placement
  • Compatible with Titan Implant Locator Pin  for easier intraoral placement and parallelism verification
  • Proudly made in Bergenfield, New Jersey, USA
  • Ideal for anterior and premolar screw-retained restorations

 

 

 Tips for Selecting the Emergence Profile and Collar Height

  • Start with the healing abutment already in place — its profile and height often guide final abutment choice.
  • Use the Titan Implant Locator Pin to verify parallelism and available height before final selection.
  • Provide the lab with: implant platform size, soft tissue thickness, desired margin position, and photos/radiographs.
  • When in doubt, select a slightly taller collar or wider profile — it’s easier to adjust than to add material later.

 

Match Emergence Profile Diameter to the Tooth Being Replaced

  • Anterior teeth (incisors, canines): Choose a narrower emergence profile (e.g., 3.8–4.5 mm) for a natural, scalloped contour and better papilla support.
  • Premolars: Medium profile (e.g., 4.5–5.5 mm).
  • Molars: Wider profile (e.g., 5.5–7.0 mm or more) for proper occlusal table and proximal contacts. The emergence profile should create a smooth, concave-to-straight transition from the implant platform to the crown at the gingival level — avoiding overly convex or abrupt angles that trap plaque or cause tissue recession.

 

 Note*Abutment available in locking only, see bar post for non-engaging option SKU#T-4ICA-12

  Recommended Accessory: Titan Implants’ Implant Locator Pin

 Please see Instruction Videos here:

 

 3. How to create emergence profile by using Titan Implants' stock abutment   (using Titan Implant Locator Pin)

 

 2. Open Tray and Final Restoration Technique for Biomet 3i Internal Connection Compatible System

 

 Note: This product uses a 0.050" Hex Screw Driver

 

0.050'' (1.27mm) Hex Screw Driver

 

 

 

Recommended Accessory

Titan Implants’ Implant Locator Pin is a straight threaded pin with a serrated

handle designed for several practical uses.

 

The implant locator pin comes in three different lengths and different threads to match various manufacturers: https://titanimplants.com/titan-implants-locator-pins/

See educational video below:

 https://titanimplants.com/educational-videos/

 Corresponding implant locator pin with 3i internal hex compatible Titan abutment: Titan Implant Locator Pin (M1.6-ILP-22)

 

 

  

 

 

With the help of the implant locator pin, minor angles can be corrected while still using straight abutments.

 

 

 

 

 

 

 

  

 

 

Other Details

Implant Manufacturer:
ZimVie / Biomet 3i
Implant System:
ZimVie Biomet 3i Certain Internal Hex
Platform Diameter:
4.0mm
Abutment Type:
Straight Locking Abutment

Add to Wish List